JOIN OUR MAILING LIST










{{item.currency}} {{pricing}}





{{item.currency}} {{pricing}} {{item.currency}} {{item.normalPrice}}



{{item.currency}} {{pricing}} - Out of Stock

Goodwe ES 4.6kW Hybrid Inverter (4.6KW Backup)
Part No: GW5048D-ES.

 

GoodWe ES series Full Hybrid inverter is best suited to grid-connected PV systems: enhancing self-consumption and providing 4.6kW backup power to essential loads in the event of loss of grid. It can intelligently control the flow of energy.

• Both MPPT charge controller and inverter are fully integrated
• Intelligent battery management function
• Capable of being grid-interactive or grid-independent
• Compatible with various Li-Ion battery types.
• 2 x MPPT inputs with a Max of 6500Wp
• 100A Battery charger
• IP65 dust-proof and water-proof rating
• 45°C full-load output
• Monitoring of inverters is free via computers or mobile phones and extremely easy to use
• Fanless, low-noise design

When using Lead-Acid battery technology with the ES/ EM Inverter range, Goodwe does not take any responsibility if the system performs below expectations.

 

BATTERY INPUT DATA

Battery Type Li-Ion or Lead-acid*1
Nominal Battery Voltage (V)  48V
Max. Charging Voltage (V) ≤60 (Configurable)
Max. Charging Current (A)*1 100A
Max. Discharging Current (A)*1 100A
Battery Capacity (Ah)*2 50~2000Ah
Charging Strategy for Li-Ion Batter Self-adaption to BMS
PV STRING INPUT DATA 
Max. DC Input Power (W) 6500W
Max. DC Input Voltage (V) 580V
MPPT Range (V) 125~550V
Start-up Voltage (V)*3 150V
MPPT Range for Full Load (V) 170~500V
Nominal DC Input Voltage (V) 360V
Max. Input Current (A) 11/11
Max. Short Current (A) 13.8/13.8A
No. of MPP Trackers 2
No. of Strings per MPP Tracker 1
AC OUTPUT DATA (ON-GRID)
Nominal Apparent Power Output to Utility Grid (VA) 4600VA
Max. Apparent Power Output to Utility Grid (VA)*4 5100VA
Max. Apparent Power from Utility Grid(VA) 9200VA
Nominal Output Voltage (V) 230V
Nominal Output Freqency (Hz) 50/60HAZ
Max. AC Current Output to Utility Grid (A) 24.5*5A
Max. AC Current From Utility Grid (A) 40A
Output Power Factor  ~1(Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output) <3%
AC OUTPUT DATA (BACK-UP)
Max. Output Apparent Power (VA) 4600VA
Peak Output Apparent Power (VA)*6 6900,10sec
Max. Output Current (A) 20A
Nominal Output Voltage (V) 230 (±2%)V
Nominal Output Freqency (Hz)  50/60 (±0.2%)Hz
Output THDv (@Linear Load) <3%
EFFICIENCY
Max. Efficiency 97.60%
Max. Battery to Load Efficiency 94.00%
Euro Efficiency 97.00%
PROTECTION
Anti-islanding Protection Integrated
PV String Input Reverse Polarity Protection Integrated
Insulation Resistor Detection Integrated
Residual Current Monitoring Unit Integrated
Output Over Current Protection Integrated
Output Short Protection Integrated
Output Over Voltage Protection Integrated
GENERAL DATA
Operating Temperature Range (°C)  -25~60
Relative Humidity  0~95%
Operating Altitude (m) ≤4000
Cooling Natural Convection
Noise (dB) <25
User Interface LED & APP
Communication with BMS*7 RS485; CAN
Communication with Meter RS485
Communicaiton with Portal Wi-Fi
Weight (kg) 30kg
Size (Width*Height*Depth mm)  516*440*184mm
Mounting  Wall Bracket
Protection Degree  IP65
Standby Self Consumption (W) <13W
Topology High Frequency Isolation
CERTIFICATIONS & STANDARDS
Grid Regulation VDE-AR-N 4105, VDE0126-1-1, AS4777.2, G83/2, CEI 0-21, NRS 097-2-1, EN50438
Safety Regulation IEC/EN62109-1&2, IEC62040-1
EMC  EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN 61000-4-16, EN 61000-4-18, EN 61000-4-29

 

 

 

 

 

 

 

Back Back to top